A Review on Analytical Method Development and Validation for Estimation of Vonoprazan Fumarate by RP-HPLC Method in Bulk and Tablet Dosage Form

 

Manasvi M. Sonavane1*, Sunila A. Patil2, Sunil P. Pawar3

1P.S.G.V.P.M’s College of Pharmacy, Shahada, Dist - Nandurbar.

Kavayitri Bahinabai Chaudhari North Maharashtra University, Jalgaon, Maharashtra, India.

2Associate Professor, P.S.G.V.P.M’s College of Pharmacy, Shahada, Dist - Nandurbar.

Kavayitri Bahinabai Chaudhari North Maharashtra University, Jalgaon, Maharashtra, India.

3Principal, P.S.G.V.P.M’s College of Pharmacy, Shahada, Dist - Nandurbar.

Kavayitri Bahinabai Chaudhari North Maharashtra University, Jalgaon, Maharashtra, India.

*Corresponding Author E-mail: manusonavane2002@gmail.com

 

ABSTRACT:

Vonoprazan fumarate is a novel potassium-competitive acid blocker (P-CAB). It is used for the treatment of acid related diseases such as gastro-esophageal reflux disease (GERD), peptic ulcer disease and eradication of Helicobacter pylori. It works by blocking potassium binding site of H+K+-ATPase enzyme and decreases gastric acid production. It has faster onset of action and gives prolonged acid suppression. Due to its increasing therapeutic importance, reliable analytical techniques are required for its quantitative estimation in pharmaceutical dosage forms and biological samples. Among the available analytical techniques, reverse phase high-performance liquid chromatography (RP-HPLC) has gained considerable attention because of its sensitivity, accuracy, and reproducibility. The present review summarizes the drug description and analytical methods reported for the determination of vonoprazan fumarate in bulk and pharmaceutical dosage form with particular emphasis on RP-HPLC techniques. Different chromatographic techniques such as UV-Visible spectroscopy, High-Performance Liquid Chromatography (HPLC), Reverse Phase High-Performance Liquid Chromatography (RP-HPLC), Ultra Performance Liquid Chromatography (UPLC), and High-Performance Thin Layer Chromatography (HPTLC) are discussed. Analytical method validation parameters in accordance with ICH guidelines described in the literature are discussed.

 

KEYWORDS: Vonoprazan Fumarate, Potassium competitive acid blocker, Analytical methods, Method validation, RP-HPLC.

 

 


 

INTRODUCTION:

Vonoprazan fumarate is a new class of acid inhibitory agent called as potassium-competitive acid blocker (P-CAB)1 used for the treatment of gastroesophageal reflux disease (GERD), eradication of Helicobacter pylori and peptic ulcers and excess acid related issues1,2. It was introduced on February 2015 by “Takeda Pharmaceutical Company Limited” (Japan). Vonoprazan was first approved in the Japanese market3. It provides rapid and sustained inhibition of gastric acid secretion. It prevents potassium ions from attaching to the proton pump in the stomach, which produces gastric acid in stomach's parietal cells2. This unique mechanism helps to improved therapeutic efficacy and increases stability under acidic conditions4. With the increasing clinical use of vonoprazan fumarate, reliable and sensitive analytical methods are required for its quantitative estimation in bulk drug substances and pharmaceutical formulations. According to literature survey various analytical techniques such as UV spectrophotometry, high-performance liquid chromatography (HPLC), and liquid chromatography–mass spectrometry (LC-MS) have been reported for its quantitative estimation. From these methods, reverse phase high-performance liquid chromatography (RP-HPLC) is widely select due to its high sensitivity, reproducibility, and suitability for routine quality control analysis. It is effective in separation of the drug from impurities, degradation products, and excipients5. According to International Council for Harmonisation (ICH) guidelines these analytical procedures are validated by evaluating parameters such as accuracy, precision, linearity, specificity, robustness, and limits of detection and limit of quantification6. This review paper focuses on the analytical techniques reported for the determination of vonoprazan fumarate, with RP-HPLC method used for pharmaceutical analysis. The study aslo shows their chromatographic conditions, validation characteristics, and applicability in pharmaceutical analysis.

 

DRUG PROFILE:

Physical and Chemical Properties:

 

Table 1. Physical and chemical properties of Vonoprazan Fumarate1,7,8,9

Drug

Vonoprazan Fumarate

Drug Category

Potassium-Competitive Acid Blocker

(P-CAB)

IUPAC Name

1-[5-(2-fluorophenyl)-1-(pyridine-3-ylsulfonyl)-1H-pyrrol-3-yl]-N-methylmethanamine fumarate

 Molecular Formula

C21H20FN3O6S

Molecular Weight

461.5 g/mol

Appearance

White to off-white crystalline powder

Solubility

Soluble in DMSO, slightly soluble in water and methanol, practically insoluble in acetone, acetonitrile

Stability

Stable under acidic and neutral conditions; Unstable under strong alkaline and oxidative conditions

Melting Point

194.80C

 

Chemical Structure:

 

Figure 1. Chemical structure of Vonoprazan Fumarate9

Mechanism of Action:

Vonoprazan is a potassium competitive acid blocker, a novel class of acid suppressants10. The intake of food increases the production of stomach acid. Proton pumps on the surface of stomach’s parietal cells are activate. H+-K+ ATPase a proton pump enzyme is activated, it leads to the release of gastric acid into the stomach. Vonoprazan selectively binds to the potassium site thereby reversibly blocking the availability of potassium to H+-K+ ATPase enzyme. By inhibiting the activity of H+-K+ ATPase, vonoprazan stops the last stage of gastric acid production. With the proton pump inhibited the secretion of gastric acid is significantly reduced. Vonoprazan maintains its inhibitory effect, providing sustained acid suppression over an extended period11,12.

 

Pharmacokinetics:

Vonoprazan exhibits time independent pharmacokinetics and steady state concentrations are achieved by day 3 to 44,7,13. Vonoprazan is acid stable and absorbed rapidly with high oral bioavailability about 85-90% with peak plasma concentrations (Cmax) reached within 1-2 hours14. Vonoprazan has alkaline pKa of 9.06, which enabled its high level of accumulation in acid spaces such as intracellular canaliculi of the parietal cells15,16. Vonoprazan has a moderate volume of distribution, it distributes well into tissues beyond the bloodstream. It is primarily bound to plasma proteins, particularly albumin12. Plasma protein binding of vonoprazan is approximately 85-88% (mainly to albumin)4,14. It is metabolized to inactive metabolites via multiple pathways by a combination of cytochrome P4507. Its plasma half-life (t1/2) was much longer than conventional PPI’s which have much shorter half lives. The half-life of 20mg tablet taken on empty stomach is about 7hours, and conventional PPI’s having shorter half lives (t1/2) of about 1-2hours. The route of elimination for vonoprazan is renal excretion. The majority of the administered dose is excreted through urine (67%) and feces (31%)17.

 

Pharmacodynamics:

Vonoprazan fumarate is a new type of potassium-competitive acid blocker that suppresses gastric acid secretion by inhibiting the gastric H+/K+-ATPase enzyme located in the secretory canaliculi of gastric parietal cells18. It selectively concentrates in the parietal cells in both the resting and stimulated states and therefore suppresses both basal as well as stimulated gastric acid secretion19. Through this action, vonoprazan causes rapid, profound, and sustained suppression of gastric acid secretion, resulting in a prolonged elevation of intragastric pH20. Vonoprazan demonstrates a faster onset of action and greater acid-inhibitory potency compared with traditional proton pump inhibitors (PPIs) such as omeprazole or lansoprazole, resulting in a more consistent elevation of intragastric pH levels over a 24 hour period21. The effect of vonoprazan is more pronounced after the first dose is compared with other conventional PPIs; a single dose of 20mg vonoprazan can increase intragastric pH to nearly 7 in around 4 hours22. These pharmacodynamic properties enable effective treatment of acid-related disorders, where maintaining a higher gastric pH improves therapeutic outcomes and enhances the efficacy of antibiotic therapy23.

 

Analytical Method Development:

Analytical chemistry is a measurement-based science which focused on improving methods for determination of the chemical composition of substances. These methods must be used inside Good Manufacturing Practices (GMP) and Good Laboratory Practices (GLP) environments and developed protocol and acceptance criteria specified in the ICH guidelines Q2 (R1)24,25. Analytical methods are continuously developed, refined, and validated to solve specific problems26. It involves the use of a various techniques and methodologies to acquire and interpret qualitative, quantitative and structural information on the nature of matter27.

 

Method Validation:

Method validation is an important process in analytical chemistry that ensures a method’s correctness and reliability. Regulatory organizations such as the International Council for Harmonisation (ICH) and the U.S. Food and Drug Administration (FDA) establish requirements for verifying analytical methods. Validation is an important component of quality assurance; it includes the efficient investigation of systems, facilities, and procedures28. Method validation is a procedure of performing numerous assessments designed to verify that an analytical test system is suitable for its intended reason and is capable of providing beneficial and legitimate analytical data29.

 

Validation Parameters:

A concept of validation was developed in the United States in 197825. Method validation is defined as the process of establishing documented evidence which provides high degree of assurance that equipment will meet the requirements for the intended analytical use30.

 

The validation parameters as per ICH guidelines are described as follows6:

 

Accuracy:

Accuracy is the agreement of closeness between the measured value or the actual value. There are several methods for determination of accuracy by the use of analytical method to a sample of known purity, or by comparison of the results of the proposed analytical method with the second accepted method24.

 

 

Precision:

Precision of an analytical method is the degree of agreement between the series of measurements obtained from multiple sampling of a same homogeneous sample under given conditions. It indicates the extent of variability or scatter in the analytical results31.

 

It divided into 3 classifications:

a.     Repeatability – It is also known as intra-assay precision and it represents the precision when the analysis is test or performed under similar operating conditions within a short time period32.

b.     Intermediate Precision – Method is tested on multiple days, instruments, analysis etc.

c.     Reproducibility – It is inter-laboratory studies33.

 

Specificity:

Specificity is the capability to assess the analyte for the presence of various components that may be expected to be present24.

 

Limit of Detection (LOD):

It is the lowest concentration of an analyte in a sample that is detectable but not always quantifiable34.

 

Limit of Quantitation (LOQ):

It is the smallest quantity of analyte in a sample that can be accurately and precisely quantified34.

 

Linearity:

The ability of the analytical process to produce test results that are exactly proportionate to the analyte concentration in the sample, within a certain range is termed as linearity35.

 

Range:

The range of an analytical method is defined as the interval between the highest concentration and lowest concentration of the analyte present in the sample24.

 

Ruggedness:

The ruggedness of an analytical method is the degree of reproducibility of test results obtained by the analysis of the same samples under a variety of conditions, such as different laboratories, analysts, instruments and days etc34.

 

Robustness:

Robustness is define by the quantum of the capability of an analytical method to remain unaffected by small, intentional changes in method parameters. It reflects the reliability of the method during normal usage. In HPLC analysis, variables that may be deliberately altered to evaluate robustness include flow rate, column temperature, sample temperature, mobile phase composition and pH33.

 

System Suitability Parameters:

The system suitability parameters such as tailing factor, retention time, resolution, and a number of the theoretical plate are used to check the sensitivity, resolution, and reproducibility of the chromatographic system are well for the analysis to be done36.

 

Analytical Techniques:

UV Spectroscopy:

The term spectroscopy is defined as the study of interaction of electromagnetic radiation with matter.1 These interactions involve absorption and emission of energy by the molecules. 2UV visible spectroscopy is the type of absorption spectroscopy in that the absorbed amount of light at each wavelength of UV and visible region of electromagnetic range is measured. This spectroscopy measures the absorption of light in range between 200-400nm for UV and in visible 400-800nm. When a source emits electromagnetic radiation (EMR) in ultra violet and visible ranges it travels through a monochromator which separates the radiations into different wavelengths. UV spectroscopy are used for both qualitative and quantitative analysis such as detection of impurities and identification of components25.

 

High-Performance Liquid Chromatography (HPLC):

Chromatography involves the mixture components separation to identify and to quantify each component between a stationary phase and a mobile phase based on their distribution. In pharmaceutical analysis HPLC is substantially used chromatographic technique due to its precision, sensitivity, and versatility37. The principal of liquid chromatography is based on adsorption25. Sample is injected into a column by high pressure pumps it deliver mixtures of different solvents, known as the mobile phase, which travel through the system and collect the sample mixture. The sample mixture is then delivered into a column, which is a filled with solid particles made of adsorbent material, known as the stationary phase. Different interactions between the sample's constituents and the adsorbent material result in varying rates of component migration. As the species move out of the column and onto particular detectors, such as UV detectors, these varying rates result in separation. Chromatogram is the graph which is generated by the detector it indicates sample components when the peaks are display. After that the graph is plotted as strength vs time or volume38. HPLC mainly used for chemical separation, purification and identification25.

 

Reverse Phase High-Performance Liquid Chromatography (RP-HPLC):

Reversed-phase liquid chromatography (RP-LC) is a type of liquid chromatography in which organic molecules are separated using a non-polar stationary phase and a polar mobile phase. In recent years, the reversed phase mode has been used for the great majority of separations and analyses performed with high-performance liquid chromatography (HPLC). The more hydrophobic the sample components are, the more they are maintained in the system in reversed phase mode39.

 

Ultra-High-Performance Liquid Chromatography (UHPLC):

Ultra-high-performance liquid chromatography (UHPLC) works on the principle as HPLC by separation of compounds based on their interaction with mobile phase and stationary phase. It allows faster, more efficient, and higher resolution separation of chemical compounds as compared with HPLC40. UHPLC uses columns that hold particles smaller than the 2.5–5μm that are typically used in HPLC41. Ultra high-performance liquid chromatography which is functions on the same presumptions as HPLC, is that as column packing particle size decreases, efficiency and thus resolution accretion rise. Higher efficiency per unit time is demonstrated by smaller particle separations in columns; nevertheless, efficiency cannot be minimized with higher mobile phase flow rates or linear velocities. After characteristics, subtle particle speed and peak resolution can be enhanced to achieve new heights. Van Deemter equations have made it commonly known that the reduction in particle size is directly proportional to the chromatographic process's efficacy. The dimension of the particles packed into the analytical column determines the link between the height equivalent of a theoretical plate (HETP) and linear velocity, as his model-characterized band broadening shows42. These shows improvement in sensitivity, resolution, and efficiency. They also lead to a faster turnaround time and a lower solvent usage, which decreases costs and improves the environmental friendliness of the technology. This method is used in pharmaceutical development, environmental testing, food safety, clinical research and biochemical analysis40.

 

High-Performance Thin Layer Chromatography (HPTLC):

High-performance thin layer chromatography (HPTLC) is an improved and automated method of thin-layer chromatography (TLC) that uses adsorption chromatography. Components are separated based on adsorption, partition or by both types, which depends upon the nature of adsorbents used on plates and solvents system used for development. The mobile phase solvent moves across the plate because of capillary action. According to their affinities towards the adsorbent, the components move. The component with higher affinity towards the stationary phase moves slower, and the component with lower affinity towards the stationary phase moves faster. Thus on a chromatographic plate different components are separated. It is used for separation, identification, and quantification of components at nanogram levels43.

 

Reported Method for Vonoprazan Fumarate:

Vonoprazan fumarate is a potassium‑competitive acid blocker (P‑CAB) used for the treatment of acid related disorders such as gastro-esophageal reflux disease, peptic ulcer disease and the eradication of Helicobacter pylori. To ensure its efficacy, safety and quality in pharmaceutical application the development of reliable analytical methods is essential. Over the years, researchers have been investigated various analytical procedures for the quantification of vonoprazan fumarate in both biological matrices and pharmaceutical formulations. These methods include UV spectrophotometry, RP-HPLC (Reverse Phase-High-Performance Liquid Chromatography), Liquid Chromatogrphy-Mass spectroscopy (LC-MS), Ultra-high-performance liquid chromatography (UPLC) all of which have contributed to improved analysis of vonoprazan fumarate. This literature survey aims to review and compare the reported RP-HPLC methods for Vonoprazan fumarate.


 

Table 2. Literature Review

Author and Year

Column Used

Mobile Phase Composition

Flow Rate (mL/min)

Detection Wavelength

Retention Time

(min)

Key Features

N. M. Alzaghal et al. (2024)31

Agilent 5 HC C18 – (150 x 4.6 mm, 5μm)

Buffer (0.01M potassium dihydrogen phosphate (1.36 g/L) and 0.02M sodium dihydrogen phosphate (2.4 g/L) in 900ml water, adjust pH 6.8 by 5N sodium hydroxide solution than complete till 1000 ml by water): Acetonitrile (65: 35 v/v)

1.0

225 nm

3.3

Simple, rapid, good accuracy and precision

Puja Gaikwad et al. (2025)26

C18 (250 × 4.6 mm, 5µm)

Acetonitrile: Phosphate buffer (58:42 % v/v)

0.8

254 nm

3.4

Good linearity, accuracy, precision, and reproducibility. No interference from excipients.

P. B. Patil et al. (2025)35

Phenomenex Kinetex C18
(100 × 4.6mm, 2.6
µm)

Phosphate buffer: Ethanol: Acetonitrile

(65:25:10 v/v/v %)

1.2

230 nm

1.825

Quality by Design (QbD) approach, robust and optimized method.

G. N. Rajage et al. (2024)2

BDS Hypersil C18 column (250 × 4.6mm, 5 µm)

Water: Acetonitrile

(95:5 v/v)

0.8

213 nm

(PDA detector)

3.9

Stability-indicating capability, eco-friendly, balance between efficiency and environmental responsibility.

 

 

P. Ravekar, S. Jawarkar et al. (2025)44

Hypersil, C18 (250 x 4.6 ID, 5 um)

Methanol: Water:

Glacial acetic acid, (75:24.5:0.5)

1.0

244 nm

3.4

Simple, accurate, precise, and sensitive method. Suitable for routine quality control analysis.

 


These reported RP-HPLC methods highlight the chromatographic conditions used for the analysis of vonoprazan fumarate, including different mobile phase compositions, detection wavelengths, column types, flow rate, retention time and key features.

 

This study summarizes the drug profile and mechanism of action of vonoprazan fumarate. In this review, previously reported analytical methods for the quantification of vonoprazan furmarate in bulk and pharmaceutical formulations are compared. Among the available techniques, reverse-phase high-performance liquid chromatography (RP-HPLC) is most commonly used method due to its high accuracy, precision, sensitivity, and robustness. Multiple studies have focused on the development and validation of reliable methods for the estimation of vonoprazan fumarate in bulk drug and dosage forms. Other methods such as UV spectroscopy, HPLC, and Stability indicating method also have also been investigated. This study makes an important contribution by organizing previous research on the development of analytical methodologies for vonoprazan fumarate. The development of eco-friendly and cost-effective methods remains an important consideration, and future research should focus on standardized, robust, and sustainable analytical approaches for vonoprazan fumarate.

 

CONFLICT OF INTEREST:

The authors have no conflicts of interest regarding this investigation.

 

REFERENCES:

1.      https://www.accessdata.fda.gov/drugsatfda_docs/label/2023/215151s000lbl.

2.      Gauri N. Rajage, Vaishali B. Jadhav, Dr. Ashish Jain, Dr. Reshma V. Jadhav, Saiesh Jogdandkar, Preeti B. Ghule, Manasi S. Mahadik, and Rupali C. Bothara. (2024). Green Assessment-Based Stability-Indicating Rp-Hplc Method Development and Validation for the Determination of Vonoprazan Fumarate in Bulk and Formulations. Revista Electronica De Veterinaria, 25(2), 1436 -1445. https://doi.org/10.69980/redvet.v25i2.1831.

3.      Moneim MMA, Hamdy MMA. Chromatographic assay of recently approved co-formulation of Vonoprazan fumarate with low dose Aspirin: AGREE, Complex MoGAPI, and RGB 12-model assessments. BMC Chem. 2024 Nov 16;18(1):230. doi: 10.1186/s13065-024-01344-7. PMID: 39548471; PMCID: PMC11568669.

4.      Jenkins H, Sakurai Y, Nishimura A, et al. Randomised clinical trial: safety, tolerability, pharmacokinetics and pharmacodynamics of repeated doses of TAK-438 (vonoprazan), a novel potassium-competitive acid blocker, in healthy male subjects. Aliment Pharmacol Ther. 2015;41(7):636–48

5.      Skoog DA, Holler FJ, Crouch SR. Principles of Instrumental Analysis. 6th ed. Boston: Cengage Learning; 2014.

6.      International Conference on Harmonization (ICH), Validation of analytical procedure: Text and methodology, Harmonized tripartite guideline, Q2 (R1), Geneva, 2005.

7.      www.fda.gov/medwatch.

8.      NIH (National center for advancing translational and Sciences), “vonoprazan fumarate,” Inxight Drugs. https://drugs.ncats.io/drug/4QW3X4AMLB#substancescar

9.      Pubchem, “Compound-Summary-(Vonoprazan fumarate).” https://pubchem.ncbi.nlm.nih.gov/compound/45375887

10.   Wong N, Reddy A, Patel A. Potassium-Competitive Acid Blockers: Present and Potential Utility in the Armamentarium for Acid Peptic Disorders. Gastroenterol Hepatol (N Y). 2022 Dec;18(12):693-700. PMID: 36865588; PMCID: PMC9972603.

11.   St Onge E, Phillips B. Vonoprazan: A New Potassium-Competitive Acid Blocker. J Pharm Technol. 2023 Jun;39(3):139-146. doi: 0.1177/87551225231166531.

12.   Vinayagam S, Mittal N, Kaushal J. Vonoprazan: a promising advancement in proton pump inhibitor therapy. International Journal of Basic and Clinical Pharmacology, 2024; 13(4), 573-579 https://doi.org/10.18203/2319-2003.

13.   Phathom Pharmaceuticals Inc. Voquezna (vonoprazan) tablets: US prescribing information. 2023. https://www.phathompharma.com/wp-content/uploads/VOQUEZNA-tablets-Prescriber-Information.pdf. Accessed 19 Dec 2023.

14.   Shirley, Matt 2024. Vonoprazan: A Review in Helicobacter pylori Infection. Drugs 84:319-327 doi-10.1007/s40265-023-01991-5.

15.   Sugano K. Vonoprazan fumarate, a novel potassium-competitive acid blocker, in the management of gastroesophageal reflux disease: safety and clinical evidence to date. Therap Adv Gastroenterol. 2018 Jan 9;11: doi: 10.1177/1756283X17745776.

16.   Shin JM, Inatomi N, Munson K, et al. Characterization of a novel potassium-competitive acid blocker of the gastric H, K-ATPase, 1-[5-(2-fluorophenyl)-1-(pyridine-3-ylsulfony)-1H-pyrrol-3-yl]-N-methyl methanamine fumarate (TAK-438). J Pharmacol Exp Therap 2011; 339: 412–420.

17.   Sampath S., and Elavarasan V. (2024). RP-HPLC Method Development and Validation for Simultaneous Estimation of Amoxicillin, Clarithromycin and Vonoprazan in Tablets. Journal of Emerging Technologies and Innovative Research (JETIR), 11(4), g500-g508.

18.   Echizen, H. (2016). The first-in-class potassium-competitive acid blocker, vonoprazan fumarate: Pharmacokinetic and pharmacodynamic considerations. Clinical Pharmacokinetics, 55(4), 409–418. https://doi.org/10.1007/s40262-015-0328-7.

19.   Yang E, Ji SC, Jang IJ, Lee S. Evaluation of CYP2C19-Mediated Pharmacokinetic Drug Interaction of Tegoprazan, Compared with Vonoprazan or Esomeprazole. Clin Pharmacokinet. 2023;62(4):599-608.

20.   Hori, Y., Imanishi, A., Matsukawa, J., Tsukimi, Y., Nishida, H., Arikawa, Y., and Hirata, Y. (2010). 1-[5-(2-Fluorophenyl)-1-(pyridin-3-ylsulfonyl)-1H-pyrrol-3-yl]-N methylmethanamine (TAK-438), a novel potassium-competitive acid blocker for the treatment of acid-related diseases. Journal of Pharmacology and Experimental Therapeutics, 335(1), 231–238.

21.   Scott, L. J. (2018). Vonoprazan: First global approval. Drugs, 78(1), 101–107.

22.   Oshima T, Miwa H.  Potent Potassium-competitive Acid Blockers: A New Era for the Treatment of Acid-related Diseases.  J Neurogastroenterol Motil 2018; 24:334-344. https://doi.org/10.5056/jnm18029

23.   Graham, D. Y., Lee, Y. C., and Wu, M. S. (2015). Rational Helicobacter pylori therapy: Evidence-based medicine rather than medicine-based evidence. Clinical Gastroenterology and Hepatology, 13(3), 486–495.

24.   Chauhan A, Mittu B, Chauhan P. Analytical method development and validation: a concise review. J Anal Bioanal Tech. 2015; 6(1): 1-5.

25.   Ramole R., Baile M., Jain A. A review: Analytical method development and validation. Systematic Reviews in Pharmacy, 2021; 12(8): 450-455.

26.   Puja S. Gaikwad, Dr. Vikas V. Patil, Mr. Pankaj S. Patil., Mr. Amol R. Pawar (2025). Development and validation of RP-HPLC method for estimation of Vonoprazan in bulk drug and formulation. International Journal of Innovative Research In Technology (IJIRT), 12(2), 2007-2014.

27.   Kealey, D., and Haines, P. J. (2002). BIOS Instant Notes in Analytical Chemistry. Garland Science.

28.   Jatto E, Okhamafe AO. An overview of pharmaceutical validation and process controls in drug development. Trop J Pharm Res 2002; 1:115-122.

29.   Rao, Tentu Nageswara. ‘Validation of Analytical Methods’. Calibration and Validation of Analytical Methods - A Sampling of Current Approaches, InTech, 25 Apr. 2018. Crossref, doi:10.5772/intechopen.72087.

30.   Lavanya G, Sunil M, Eswarudu MM, Eswaraiah MC, Harisudha K, Spandana BN, et al. Analytical method validation: an updated review. Int J Pharm Sci Res 2013; 4:1280.

31.   Alzaghal, N. M., El-Mossalamy, E. S. H., and El-Sayed, G. O. (2024). Method Development and Validation for Estimation of Vonoprazan by RP-HPLC method in bulk and tablets dosage form. Egyptian Journal of Chemistry, 67(2), 145-159.

32.   Alka N Choudharya, Tanya Sehgal, 2021. A review on pharmaceutical validation and its implications. Jour. of Med. P’ceutical and Allied. Sci. V 10 - I 6, 1927, P- 3951-3959. doi:10.22270/ jmpas. 2021.V10I6.1927.

33.   MS Patil, RR Patil, SS Chalikwar, SJ Surana and SD Firke. Analytical method development and validation: A review. International Journal of Pharmaceutical and Biological Science Archive 2019; 7(3), 70-81.

34.   Ashvini Pawar, Shivnath Shinde, Shrikrishna Baokar, Rajendra Patil. Analytical method validation: ICH and USP perspectives. International Journal of Research and Review. 2025; 12(8): 70-77. DOI: https://doi.org/10.52403/ijrr.20250809.

35.   Patil, P. and Patil, G. and Sonawane, R. and Bagul, Vijay and Tiwari, Anand. (2025). Development and Validation of an Eco-friendly RP-HPLC Method for Vonoprazan: A QbD Approach. Chromatographia. 88. 809-826. 10.1007/s10337-025-04440-5.

36.   Sharma, S., Goyal, S., and Chauhan, K. (2018). A REVIEW ON ANALYTICAL METHOD DEVELOPMENT AND VALIDATION. International Journal of Applied Pharmaceutics, 10(6), 8–15. https://doi.org/10.22159/ijap.2018v10i6.28279.

37.   B.K. Sharma. 2004 “Instrumental Methods Of Chemical Analysis.”, Goel Publishing House, Meerut, 20th edition: 163-167.

38.   Kazakevich, Yuri; LoBrutto, Rosario, eds. (2007). HPLC for pharmaceutical scientists. Hoboken, NJ: Wiley- Interscience. ISBN 978-0-471-68162-5.

39.   Ganesh, V.; Poorna Basuri, P.; Sahini, K.; Nalini, C.N. (2023). "Retention behaviour of analytes in reversed‐phase high‐performance liquid chromatography—A review". Biomedical Chromatography. 37 (7): e5482. doi:10.1002/bmc.5482. ISSN 0269-3879. PMID 35962484. S2CID 251540223.

40.   Ahamed, Mr and M. Hariharan, M. Hariharan and G.Hemamalini, G. Hemamalini and Nowfaldeen, M.Harshath and M.Hemalatha, M.Hemalatha and R.Hemnath, R.Hemnath. (2025). Analytical Method and Validation for Estimation of Vonoprazan in Pharmaceutical Dosage Form – A Review. International Journal of Pharmaceutical Research and Applications. 10. 177-185. 10.35629/4494-1005177185.

41.   Thomas H. Walter, Richard W. Andrews, Richard, Recent innovations in UHPLC columns and instrumentation. Trends in Analytical Chemistry (2014), 63, 14–20. Doi: 10.1016/j.trac.2014.07.016.

42.   Rathod, R. H., Chaudhari, S. R., Patil, A. S. et al. Ultra-high-performance liquid chromatography-MS/MS (UHPLC-MS/MS) in practice: analysis of drugs and pharmaceutical formulations. Future J Pharm Sci 5, 6 (2019). https://doi.org/10.1186/s43094-019-0007-8.

43.   Shukla, R., Singh, P. K., and Upadhyay, S. (2023). A comprehensive review of high-performance thin layer chromatography (HPTLC). IJPPR Human, 27(1), 398-410.

44.   Ravekar P. G., and Jawarkar, S. G. (2025). Analytical method development and validation for simultaneous estimation of API in pharmaceutical dosage form by using RP-HPLC method. International Journal for Research Trends and Innovation, 10(8), a600-a609 https://www.ijrti.org (ISSN: 2456-3315).

 

 

 

Received on 05.05.2026      Revised on 09.06.2026

Accepted on 14.07.2026      Published on 12.10.2026

Available online from October 21, 2026

Asian Journal of Pharmaceutical Analysis. 2026; 16(4):318-324.

DOI: 10.52711/2231-5675.2026.00049

©Asian Pharma Press All Right Reserved

 

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License. Creative Commons License.